Epi-3015 PDA

SALIENT FEATURES:
  • Motion controlled independent servo driven stations
  • Capable of running all types of forming materials
  • Quick and easy changeovers
  • Output up to 450 blisters/min
FEATURES:
  • Alu/alu forming capability with forming depth correction on the fly
  • Continuous monitoring of sealing pressure for consistent blister quality
  • Designed to run PVC, PVC/PVDC, PVC/ACLAR, PET and PETG combination films
  • All work station, servo motor driven
  • Switch from thermo-forming mode to cold-forming mode by selection on the HMI
  • Touch screen for operator interface
  • Robust 4-column station design for durability and reliability
  • Retractable sealing during machine stop
  • Separate reject containers for scrap and misfilled blisters
  • Slide-in tooling for quick and easy changeovers
  • Can be connected with any new or existing cartoning equipment
  • Optimum performance, flexibility
OPTIONAL FEATURES:
  • Batch report and audit trail
  • 21 CFR part 11 compatibility
  • Multi-color and/or multi-product feed system available.
  • Optional isolation of product fill area availabe
  • Dedicated feed system available for any kind and shape of oral solid dose products.
TECHNICAL SPECIFICATIONS
MODEL EPI-3015 PDA
Max. Blister Forming Area 300 mm web width X 166 mm advance
Max. Forming Depth 12 mm
Base Film Roll core diameter 72-76 mm
Max. Roll core diameter 440 mm
Lidding Foil Roll core diameter 72-76 mm
Max. Roll core diameter 250 mm
Mechanical Speed Max. 45 cycles/min
Operational Speed Max. 40 cycles/min
UTILITIES REQUIRMENTS
Power Supply 415 V 3 Phase + N + E 50 Hz
Connected Load (Supplied by UPS) 20 KW
Avarage Load (Supplied by UPS) 15 KW
Connected Load (Supplied by Separate mains only for heating load) 32 KW
Avarage Load (Supplied by Separate mains only for heating load) 25 KW
Compressed Air 450 NLPM @ 6 kg/cm2
Chilled Water 300 lph @ 3 kg/cm2
Weight 3,000 kg approx.
SHIPPING DIMENSIONS FOR BASIC MACHINE
DIMENSIONS NET WT. GR. WT.
220" X 60" X 82" 3750 kg 4150 kg

IT IS RECOMMENDED THAT THE MACHINE IS INSTALLED IN AIR CONDITIONED PREMISES HAVING ROOM TEMPERATURE OF 22 0C TO 26 0C TO ENSURE EFFICIENT WORKING” NOTE: SPECIFICATIONS ARE INDICATIVE AND WE RESERVE THE RIGHT TO MODIFY THEM WITHOUT PRIOR NOTICE.